{"_buckets": {"deposit": "22d8c65e-f9f5-430a-81e9-52fa0bf8f6e4"}, "_deposit": {"created_by": 3, "id": "5188", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "5188"}, "status": "published"}, "_oai": {"id": "oai:nitech.repo.nii.ac.jp:00005188", "sets": ["31"]}, "author_link": ["17545", "8610", "17539", "17541", "17543", "17542", "17544", "16261"], "item_10001_biblio_info_28": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2004-05", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "5", "bibliographicPageEnd": "1368", "bibliographicPageStart": "1366", "bibliographicVolumeNumber": "75", "bibliographic_titles": [{"bibliographic_title": "REVIEW OF SCIENTIFIC INSTRUMENTS"}]}]}, "item_10001_description_36": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "A new field-emission x-ray radiography system based on our design is described. The key component of the system is a triode-type x-ray source with a built-in nanostructured electron source. The electron source is comprised of palladium-induced carbon nanofibers, which continue to field-emit electrons for more than 10 h at 2×10-7Torr with a fluctuation of ±8%. Feedback control of the potential of the electron-extracting electrode, or the gate, reduces the current fluctuation to ±0.5%, but this current regulation does little to improve the image resolution. Our system provides sharp x-ray images of both biological and nonbiological samples.", "subitem_description_type": "Other"}]}, "item_10001_description_38": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_10001_full_name_27": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "8610", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "1000030236715", "nameIdentifierScheme": "NRID", "nameIdentifierURI": "http://rns.nii.ac.jp/nr/1000030236715"}], "names": [{"name": "種村, 眞幸"}]}]}, "item_10001_publisher_29": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "American Institute of Physics"}]}, "item_10001_relation_34": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "10.1063/1.1711140"}], "subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://dx.doi.org/10.1063/1.1711140", "subitem_relation_type_select": "DOI"}}]}, "item_10001_source_id_30": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "00346748", "subitem_source_identifier_type": "ISSN"}]}, "item_10001_source_id_32": {"attribute_name": "書誌レコードID(NCID)", "attribute_value_mlt": [{"subitem_source_identifier": "AA00817730", "subitem_source_identifier_type": "NCID"}]}, "item_10001_version_type_33": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Senda, S.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "17539", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tanemura, Masaki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "8610", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "1000030236715", "nameIdentifierScheme": "NRID", "nameIdentifierURI": "http://rns.nii.ac.jp/nr/1000030236715"}]}, {"creatorNames": [{"creatorName": "Sakai, Y.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "17541", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ichikawa, Y.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "17542", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kita, S.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "17543", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Otsuka, T.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "17544", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Haga, A.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "17545", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Okuyama, F.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "16261", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-01-25"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "RSI 75_1366.pdf", "filesize": [{"value": "432.6 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensefree": "Copyright (2004) American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics.The following article appeared in Review of Scientific Instruments, 75(5), pp.1366- 1368 ; 2004 and may be found at http://link.aip.org/link/?rsi/75/1366", "licensetype": "license_free", "mimetype": "application/pdf", "size": 432600.0, "url": {"label": "本文_fulltext", "url": "https://nitech.repo.nii.ac.jp/record/5188/files/RSI 75_1366.pdf"}, "version_id": "9576fdb6-ab7f-48cd-809a-031d49296296"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "New field-emission x-ray radiography system", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "New field-emission x-ray radiography system", "subitem_title_language": "en"}]}, "item_type_id": "10001", "owner": "3", "path": ["31"], "permalink_uri": "https://nitech.repo.nii.ac.jp/records/5188", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-11-06"}, "publish_date": "2012-11-06", "publish_status": "0", "recid": "5188", "relation": {}, "relation_version_is_last": true, "title": ["New field-emission x-ray radiography system"], "weko_shared_id": 3}
New field-emission x-ray radiography system
https://nitech.repo.nii.ac.jp/records/5188
https://nitech.repo.nii.ac.jp/records/518840c60c39-1e61-4e50-92b8-94fe0e04739a
名前 / ファイル | ライセンス | アクション |
---|---|---|
本文_fulltext (432.6 kB)
|
Copyright (2004) American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics.The following article appeared in Review of Scientific Instruments, 75(5), pp.1366- 1368 ; 2004 and may be found at http://link.aip.org/link/?rsi/75/1366
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-11-06 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | New field-emission x-ray radiography system | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Senda, S.
× Senda, S.× Tanemura, Masaki× Sakai, Y.× Ichikawa, Y.× Kita, S.× Otsuka, T.× Haga, A.× Okuyama, F. |
|||||
著者別名 | ||||||
姓名 | 種村, 眞幸 | |||||
書誌情報 |
REVIEW OF SCIENTIFIC INSTRUMENTS 巻 75, 号 5, p. 1366-1368, 発行日 2004-05 |
|||||
出版者 | ||||||
出版者 | American Institute of Physics | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 00346748 | |||||
書誌レコードID(NCID) | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA00817730 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | http://dx.doi.org/10.1063/1.1711140 | |||||
関連名称 | 10.1063/1.1711140 | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | A new field-emission x-ray radiography system based on our design is described. The key component of the system is a triode-type x-ray source with a built-in nanostructured electron source. The electron source is comprised of palladium-induced carbon nanofibers, which continue to field-emit electrons for more than 10 h at 2×10-7Torr with a fluctuation of ±8%. Feedback control of the potential of the electron-extracting electrode, or the gate, reduces the current fluctuation to ±0.5%, but this current regulation does little to improve the image resolution. Our system provides sharp x-ray images of both biological and nonbiological samples. | |||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | application/pdf |