WEKO3
アイテム
Laser flash method for measuring thermal conductivity of liquids - Application to low thermal conductivity liquids
https://nitech.repo.nii.ac.jp/records/3710
https://nitech.repo.nii.ac.jp/records/37102595cf44-60db-42ce-9265-bf2f7a99543c
名前 / ファイル | ライセンス | アクション |
---|---|---|
本文_fulltext (656.8 kB)
|
Copyright (1978) American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics.The following article appeared in Review of Scientific Instruments, 49(9), pp.1305- 1314 ; 1978 and may be found at http://link.aip.org/link/?rsi/49/1305
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-11-06 | |||||
タイトル | ||||||
タイトル | Laser flash method for measuring thermal conductivity of liquids - Application to low thermal conductivity liquids | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Tada, Yutaka
× Tada, Yutaka× Harada, Makoto× Tanigaki, Masataka× Eguchi, Wataru |
|||||
著者別名 | ||||||
識別子Scheme | WEKO | |||||
識別子 | 8565 | |||||
姓名 | Tada, Yutaka | |||||
書誌情報 |
REVIEW OF SCIENTIFIC INSTRUMENTS 巻 49, 号 9, p. 1305-1314, 発行日 1978-09 |
|||||
出版者 | ||||||
出版者 | American Institute of Physics | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 00346748 | |||||
書誌レコードID(NCID) | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA00817730 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | http://dx.doi.org/10.1063/1.1135573 | |||||
関連名称 | 10.1063/1.1135573 | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | A laser flash method developed for the measurement of thermal conductivity of solids was applied to liquids of low thermal conductivity. The sample liquid was sandwiched in between a small thin metal disk and a sample holder. When the laser beam is absorbed in the front surface of the metal disk, the temperature of the disk quickly rises about 2 K and heat then flows downwards through the sample liquid as one‐dimensional heat flow. The thermal conductivity of liquid can be obtained from the temperature fall of the disk without employing any reference materials and also without measuring the thickness of the sample liquid layer. Thermal conductivities of water and toluene near room temperature were measured by this method with a mean deviation of 2.6%. This laser flash method may be applied to the measurement of the thermal conductivity of liquids such as molten salts at elevated temperatures. | |||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | application/pdf |