Realizing Highly Localized Exposure in Small Animals with Absorbing Material Covered Holder to Test Biological Effects of 1.5 GHz Cellular Telephones
https://nitech.repo.nii.ac.jp/records/5137
https://nitech.repo.nii.ac.jp/records/513766f4adfe-d5de-430b-9b82-83a54d6edbf6
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
Copyright(c)2003 IEICE http://search.ieice.org/index.html
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2013-06-25 | |||||||||||||||
タイトル | ||||||||||||||||
タイトル | Realizing Highly Localized Exposure in Small Animals with Absorbing Material Covered Holder to Test Biological Effects of 1.5 GHz Cellular Telephones | |||||||||||||||
言語 | en | |||||||||||||||
言語 | ||||||||||||||||
言語 | eng | |||||||||||||||
資源タイプ | ||||||||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||||||||
資源タイプ | journal article | |||||||||||||||
著者 |
王, 建青
× 王, 建青
× Fujiwara, Osamu
|
|||||||||||||||
著者別名 | ||||||||||||||||
姓名 | Wang, Jianqing | |||||||||||||||
言語 | en | |||||||||||||||
姓名 | 王, 建青 | |||||||||||||||
言語 | ja | |||||||||||||||
姓名 | オウ, ケンセイ | |||||||||||||||
言語 | ja-Kana | |||||||||||||||
著者別名 | ||||||||||||||||
姓名 | 藤原, 修 | |||||||||||||||
書誌情報 |
en : IEICE Transactions on Communications 巻 E86-B, 号 5, p. 1660-1665, 発行日 2003-05-01 |
|||||||||||||||
出版者 | ||||||||||||||||
出版者 | Institute of Electronics, Information and Communication Engineers | |||||||||||||||
言語 | en | |||||||||||||||
ISSN | ||||||||||||||||
収録物識別子タイプ | ISSN | |||||||||||||||
収録物識別子 | 0916-8516 | |||||||||||||||
item_10001_source_id_32 | ||||||||||||||||
収録物識別子タイプ | NCID | |||||||||||||||
収録物識別子 | AA10826261 | |||||||||||||||
出版タイプ | ||||||||||||||||
出版タイプ | VoR | |||||||||||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||||||||||||
内容記述 | ||||||||||||||||
内容記述タイプ | Other | |||||||||||||||
内容記述 | In testing the possible biological effects of electromagnetic exposure from cellular telephones in small animals such as mice, it is essential to realize a highly localized head exposure as close as possible to that due to cellular telephones in humans. In this study, a 1.5GHz exposure setup was developed which has a highly localized specific absorption rate (SAR) of 2W/kg in the mouse brain and a low whole-body averaged SAR of 0.27W/kg. The low whole-body averaged SAR was realized by using a flexible magnetic sheet attachment on the mouse holder. Its validity has been carefully examined by both numerical simulation with an anatomically based mouse model and experimental simulation with a solid mouse phantom. Good agreement was obtained between the numerical and experimental results, which confirmed the effectiveness of the magnetic sheet attachment to the mouse holder. | |||||||||||||||