ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 研究論文

Methacrylate-ester-based Reversed Phase Monolithic Columns for High Speed Separation Prepared by Low Temperature UV Photo-polymerization

https://nitech.repo.nii.ac.jp/records/5463
https://nitech.repo.nii.ac.jp/records/5463
1e96fce7-615f-4315-a2f5-69bd024d19f0
名前 / ファイル ライセンス アクション
AS 本文_fulltext (766.1 kB)
2009 cThe Japan Society for Analytical Chemistry
Item type 学術雑誌論文 / Journal Article(1)
公開日 2012-11-06
タイトル
タイトル Methacrylate-ester-based Reversed Phase Monolithic Columns for High Speed Separation Prepared by Low Temperature UV Photo-polymerization
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Hirano, Tomohiko

× Hirano, Tomohiko

en Hirano, Tomohiko

Search repository
Kitagawa, Shinya

× Kitagawa, Shinya

en Kitagawa, Shinya

Search repository
Ohtani, Hajime

× Ohtani, Hajime

en Ohtani, Hajime

Search repository
著者別名
姓名 北川, 慎也
著者別名
姓名 Ohtani, Hajime
書誌情報 en : Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

巻 25, 号 9, p. 1107-1113, 発行日 2009-09
出版者
出版者 The Japan Society for Analytical Chemistry
言語 en
ISSN
収録物識別子タイプ ISSN
収録物識別子 0910-6340
item_10001_source_id_32
収録物識別子タイプ NCID
収録物識別子 AA10500785
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
item_10001_relation_34
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 http://dx.doi.org/10.2116/analsci.25.1107
関連名称 10.2116/analsci.25.1107
内容記述
内容記述タイプ Other
内容記述 Butyl methacrylate-based reversed phase capillary monolithic columns were prepared using ultraviolet (UV) photo-polymerization. The effects of two photo-polymerization conditions (UV irradiation intensity and polymerization temperature) on the column characteristics were investigated. Both the higher UV irradiation intensity and the lower polymerization temperature lead to the superior column efficiency. The column prepared under the optimized conditions was evaluated through the separation of the uracil and five alkylbenzenes in the linear flow rate range of 1 - 110 mm/s. At 1 mm/s, all analytes were well separated (N = 36000 - 45000 plates/m). The high speed separation within 8 s was performed at 110 mm/s (back pressure, 33 MPa) at room temperature, whereas the peaks eluted earlier were overlapped partially. The relationship between the flow rate and the back pressure indicated that some kind of structural change of the monolith might occur in 50 - 110 mm/s, although no visible or hysteresis changes of the monolith were observed after the measurement.
言語 en
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 13:31:48.338246
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3