{"_buckets": {"deposit": "7d729065-5fe5-43a5-8d13-9392f04d18d5"}, "_deposit": {"created_by": 3, "id": "6173", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "6173"}, "status": "published"}, "_oai": {"id": "oai:nitech.repo.nii.ac.jp:00006173", "sets": ["31"]}, "author_link": ["8708", "22144", "10033", "10032"], "item_10001_alternative_title_24": {"attribute_name": "その他(別言語等)のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Management of Change for Plant Alarm System based on Business Process Model of Plant Lifecycle Engineering"}]}, "item_10001_biblio_info_28": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2014", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "229", "bibliographicPageStart": "224", "bibliographicVolumeNumber": "40", "bibliographic_titles": [{"bibliographic_title": "化学工学論文集"}]}]}, "item_10001_description_36": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "ISA(International Society of Automation)により,プラントアラームシステムに対するアラームマネジメントライフサイクルが提案されている.このサイクルを実現するためには,プラントアラームシステムの変更管理を適切に実行するための業務プロセスモデルが必要となる.プラントライフサイクルエンジニアリングの業務プロセスモデルに基づき,ISAのアラームマネジメントライフサイクルに沿った業務プロセスモデルを構築し,そこからプラントアラームシステムの変更管理を行うための業務フローを導出する方法が有効だと考えられる.業務の列挙だけでなく,業務間で交換される情報,当該業務にて利用するツールや手法などを業務プロセスモデルや業務フロー上に明示することで,プラントアラームの設計や性能監視用に開発されてきた既存のツールや手法の位置づけ,および,新たにどのようなツールや手法が必要とされるかが明確になる.本論文では,プラントアラームシステムの変更管理の業務プロセスモデルと業務フローのあり方,および,プラントアラームの設計や性能監視用にこれまで提案されてきたツールや手法について概説する.", "subitem_description_type": "Other"}]}, "item_10001_description_38": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_10001_full_name_27": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "8708", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "1000080314079 ", "nameIdentifierScheme": "NRID", "nameIdentifierURI": "http://rns.nii.ac.jp/nr/1000080314079 "}], "names": [{"name": "Hamaguchi, Takashi"}]}]}, "item_10001_publisher_29": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "化学工学会"}]}, "item_10001_relation_34": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "10.1252/kakoronbunshu.40.224 "}], "subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1252/kakoronbunshu.40.224 ", "subitem_relation_type_select": "DOI"}}]}, "item_10001_relation_35": {"attribute_name": "論文ID(NAID)", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "130004855786"}], "subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://ci.nii.ac.jp/naid/130004855786", "subitem_relation_type_select": "NAID"}}]}, "item_10001_source_id_30": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0386216X", "subitem_source_identifier_type": "ISSN"}]}, "item_10001_source_id_32": {"attribute_name": "書誌レコードID(NCID)", "attribute_value_mlt": [{"subitem_source_identifier": "AN00037234", "subitem_source_identifier_type": "NCID"}]}, "item_10001_version_type_33": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "武田, 和宏"}], "nameIdentifiers": [{"nameIdentifier": "10033", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "浜口, 孝司"}, {"creatorName": "ハマグチ, タカシ", "creatorNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "8708", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "1000080314079 ", "nameIdentifierScheme": "NRID", "nameIdentifierURI": "http://rns.nii.ac.jp/nr/1000080314079 "}]}, {"creatorNames": [{"creatorName": "木村, 直樹"}], "nameIdentifiers": [{"nameIdentifier": "10032", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "野田, 賢"}], "nameIdentifiers": [{"nameIdentifier": "22144", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-01-26"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "HamaguchiTakashi_2014_A2.pdf", "filesize": [{"value": "823.0 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensefree": "(c)化学工学会", "licensetype": "license_free", "mimetype": "application/pdf", "size": 823000.0, "url": {"label": "本文_fulltext", "url": "https://nitech.repo.nii.ac.jp/record/6173/files/HamaguchiTakashi_2014_A2.pdf"}, "version_id": "91facf02-c238-4f31-a219-83cca787b2e7"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "プラントアラームシステム", "subitem_subject_scheme": "Other"}, {"subitem_subject": "アラームマネジメントライフサイクル", "subitem_subject_scheme": "Other"}, {"subitem_subject": "業務プロセスモデル", "subitem_subject_scheme": "Other"}, {"subitem_subject": "変更管理", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "プラントライフサイクルエンジニアリングの業務プロセスモデルに基づくプラントアラームシステムの変更管理", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "プラントライフサイクルエンジニアリングの業務プロセスモデルに基づくプラントアラームシステムの変更管理"}]}, "item_type_id": "10001", "owner": "3", "path": ["31"], "permalink_uri": "https://nitech.repo.nii.ac.jp/records/6173", "pubdate": {"attribute_name": "公開日", "attribute_value": "2018-01-26"}, "publish_date": "2018-01-26", "publish_status": "0", "recid": "6173", "relation": {}, "relation_version_is_last": true, "title": ["プラントライフサイクルエンジニアリングの業務プロセスモデルに基づくプラントアラームシステムの変更管理"], "weko_shared_id": 3}
プラントライフサイクルエンジニアリングの業務プロセスモデルに基づくプラントアラームシステムの変更管理
https://nitech.repo.nii.ac.jp/records/6173
https://nitech.repo.nii.ac.jp/records/617381427651-4177-4b05-b407-636afa540316
名前 / ファイル | ライセンス | アクション |
---|---|---|
本文_fulltext (823.0 kB)
|
(c)化学工学会
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-01-26 | |||||
タイトル | ||||||
タイトル | プラントライフサイクルエンジニアリングの業務プロセスモデルに基づくプラントアラームシステムの変更管理 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | プラントアラームシステム | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | アラームマネジメントライフサイクル | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 業務プロセスモデル | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 変更管理 | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
その他(別言語等)のタイトル | ||||||
その他のタイトル | Management of Change for Plant Alarm System based on Business Process Model of Plant Lifecycle Engineering | |||||
著者 |
武田, 和宏
× 武田, 和宏× 浜口, 孝司× 木村, 直樹× 野田, 賢 |
|||||
著者別名 | ||||||
姓名 | Hamaguchi, Takashi | |||||
書誌情報 |
化学工学論文集 巻 40, 号 3, p. 224-229, 発行日 2014 |
|||||
出版者 | ||||||
出版者 | 化学工学会 | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0386216X | |||||
書誌レコードID(NCID) | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00037234 | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1252/kakoronbunshu.40.224 | |||||
関連名称 | 10.1252/kakoronbunshu.40.224 | |||||
論文ID(NAID) | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | NAID | |||||
関連識別子 | https://ci.nii.ac.jp/naid/130004855786 | |||||
関連名称 | 130004855786 | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | ISA(International Society of Automation)により,プラントアラームシステムに対するアラームマネジメントライフサイクルが提案されている.このサイクルを実現するためには,プラントアラームシステムの変更管理を適切に実行するための業務プロセスモデルが必要となる.プラントライフサイクルエンジニアリングの業務プロセスモデルに基づき,ISAのアラームマネジメントライフサイクルに沿った業務プロセスモデルを構築し,そこからプラントアラームシステムの変更管理を行うための業務フローを導出する方法が有効だと考えられる.業務の列挙だけでなく,業務間で交換される情報,当該業務にて利用するツールや手法などを業務プロセスモデルや業務フロー上に明示することで,プラントアラームの設計や性能監視用に開発されてきた既存のツールや手法の位置づけ,および,新たにどのようなツールや手法が必要とされるかが明確になる.本論文では,プラントアラームシステムの変更管理の業務プロセスモデルと業務フローのあり方,および,プラントアラームの設計や性能監視用にこれまで提案されてきたツールや手法について概説する. | |||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | application/pdf |