{"_buckets": {"deposit": "45a180e1-4155-4411-b09f-2245a57153cd"}, "_deposit": {"created_by": 3, "id": "6370", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "6370"}, "status": "published"}, "_oai": {"id": "oai:nitech.repo.nii.ac.jp:00006370", "sets": ["31"]}, "author_link": ["8718", "21636", "8753"], "item_10001_biblio_info_28": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2016-11-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "11", "bibliographicPageEnd": "2449", "bibliographicPageStart": "2442", "bibliographicVolumeNumber": "99", "bibliographic_titles": [{}, {"bibliographic_title": "IEICE Transactions on Communications", "bibliographic_titleLang": "en"}]}]}, "item_10001_description_36": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "When using a wireless capsule endoscope (WCE), it is important to know WCE location. In this paper, we focus on a time of arrival (TOA)-based localization technique, as it has better location estimation performance than other radio frequency-based techniques. However, the propagation speed of signals transmitted from inside of a human body varies depending on which biological tissues they pass through. For this reason, almost all of conventional TOA-based methods have to obtain the relative permittivity of the passed biological tissues or the propagation speed beforehand through another measurement system, i.e., magnetic resonance imaging (MRI) or computational tomography (CT). To avoid such troublesome pre-measurement, we propose a hybrid TOA/received signal strength indicator (RSSI)-based method, which can simultaneously estimate the WCE location and the averaged relative permittivity of the human body. First, we derive the principle of RSSI-based relative permittivity estimation from an finite difference time domain (FDTD) simulation. Second, we combine the TOA-based localization and the proposed RSSI-based relative permittivity estimation, and add them to the particle filter tracking technique. Finally, we perform computer simulations to evaluate the estimation accuracy of the proposed method. The simulation results show that the proposed method can accomplish good localization performance, 1.3mm, without pre-measurement of the human body structure information.", "subitem_description_type": "Other"}]}, "item_10001_description_38": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_10001_full_name_27": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "8718", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "1000040611116", "nameIdentifierScheme": "NRID", "nameIdentifierURI": "http://rns.nii.ac.jp/nr/1000040611116"}], "names": [{"name": "安在, 大祐"}]}, {"nameIdentifiers": [{"nameIdentifier": "8753", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "1000070250694", "nameIdentifierScheme": "NRID", "nameIdentifierURI": "http://rns.nii.ac.jp/nr/1000070250694"}], "names": [{"name": "王, 建青"}]}]}, "item_10001_publisher_29": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Institute of Electronics, Information and Communication Engineers "}]}, "item_10001_relation_34": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "10.1587/transcom.2015EBP3439"}], "subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1587/transcom.2015EBP3439", "subitem_relation_type_select": "DOI"}}]}, "item_10001_relation_35": {"attribute_name": "論文ID(NAID)", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "130005268111"}], "subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://ci.nii.ac.jp/naid/130005268111", "subitem_relation_type_select": "NAID"}}]}, "item_10001_relation_37": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "http://www.ieice.org/jpn/books/transaction.html"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.ieice.org/jpn/books/transaction.html", "subitem_relation_type_select": "URI"}}]}, "item_10001_source_id_30": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "09168516", "subitem_source_identifier_type": "ISSN"}]}, "item_10001_source_id_32": {"attribute_name": "書誌レコードID(NCID)", "attribute_value_mlt": [{"subitem_source_identifier": "AA11510208", "subitem_source_identifier_type": "NCID"}]}, "item_10001_version_type_33": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Ito, Takahiro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "21636", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Anzai, Daisuke", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "8718", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "1000040611116", "nameIdentifierScheme": "NRID", "nameIdentifierURI": "http://rns.nii.ac.jp/nr/1000040611116"}]}, {"creatorNames": [{"creatorName": "Wang, Jianqing", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "8753", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "1000070250694", "nameIdentifierScheme": "NRID", "nameIdentifierURI": "http://rns.nii.ac.jp/nr/1000070250694"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-11-12"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "AnzaiDaisuke_2016_P1.pdf", "filesize": [{"value": "2.4 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensefree": "copyright(C)2016 IEICE", "licensetype": "license_free", "mimetype": "application/pdf", "size": 2400000.0, "url": {"label": "本文_fulltext", "url": "https://nitech.repo.nii.ac.jp/record/6370/files/AnzaiDaisuke_2016_P1.pdf"}, "version_id": "80c47ae5-6f24-4b79-b8fc-03249a3cd465"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "WCE", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "localization", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "BAN", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "TOA", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "RSSI", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "particle filter", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Hybrid TOA/RSSI-Based Wireless Capsule Endoscope Localization with Relative Permittivity Estimation", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Hybrid TOA/RSSI-Based Wireless Capsule Endoscope Localization with Relative Permittivity Estimation", "subitem_title_language": "en"}]}, "item_type_id": "10001", "owner": "3", "path": ["31"], "permalink_uri": "https://nitech.repo.nii.ac.jp/records/6370", "pubdate": {"attribute_name": "公開日", "attribute_value": "2018-11-12"}, "publish_date": "2018-11-12", "publish_status": "0", "recid": "6370", "relation": {}, "relation_version_is_last": true, "title": ["Hybrid TOA/RSSI-Based Wireless Capsule Endoscope Localization with Relative Permittivity Estimation"], "weko_shared_id": 3}
Hybrid TOA/RSSI-Based Wireless Capsule Endoscope Localization with Relative Permittivity Estimation
https://nitech.repo.nii.ac.jp/records/6370
https://nitech.repo.nii.ac.jp/records/6370a49fde9b-41db-4442-82f3-d47b0470c0b7
名前 / ファイル | ライセンス | アクション |
---|---|---|
本文_fulltext (2.4 MB)
|
copyright(C)2016 IEICE
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-11-12 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Hybrid TOA/RSSI-Based Wireless Capsule Endoscope Localization with Relative Permittivity Estimation | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | WCE | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | localization | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | BAN | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | TOA | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | RSSI | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | particle filter | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Ito, Takahiro
× Ito, Takahiro× Anzai, Daisuke× Wang, Jianqing |
|||||
著者別名 | ||||||
姓名 | 安在, 大祐 | |||||
著者別名 | ||||||
姓名 | 王, 建青 | |||||
書誌情報 |
en : IEICE Transactions on Communications 巻 99, 号 11, p. 2442-2449, 発行日 2016-11-01 |
|||||
出版者 | ||||||
出版者 | Institute of Electronics, Information and Communication Engineers | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 09168516 | |||||
書誌レコードID(NCID) | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA11510208 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1587/transcom.2015EBP3439 | |||||
関連名称 | 10.1587/transcom.2015EBP3439 | |||||
論文ID(NAID) | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | NAID | |||||
関連識別子 | https://ci.nii.ac.jp/naid/130005268111 | |||||
関連名称 | 130005268111 | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | When using a wireless capsule endoscope (WCE), it is important to know WCE location. In this paper, we focus on a time of arrival (TOA)-based localization technique, as it has better location estimation performance than other radio frequency-based techniques. However, the propagation speed of signals transmitted from inside of a human body varies depending on which biological tissues they pass through. For this reason, almost all of conventional TOA-based methods have to obtain the relative permittivity of the passed biological tissues or the propagation speed beforehand through another measurement system, i.e., magnetic resonance imaging (MRI) or computational tomography (CT). To avoid such troublesome pre-measurement, we propose a hybrid TOA/received signal strength indicator (RSSI)-based method, which can simultaneously estimate the WCE location and the averaged relative permittivity of the human body. First, we derive the principle of RSSI-based relative permittivity estimation from an finite difference time domain (FDTD) simulation. Second, we combine the TOA-based localization and the proposed RSSI-based relative permittivity estimation, and add them to the particle filter tracking technique. Finally, we perform computer simulations to evaluate the estimation accuracy of the proposed method. The simulation results show that the proposed method can accomplish good localization performance, 1.3mm, without pre-measurement of the human body structure information. | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.ieice.org/jpn/books/transaction.html | |||||
関連名称 | http://www.ieice.org/jpn/books/transaction.html | |||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | application/pdf |