{"created":"2023-05-15T12:35:30.114033+00:00","id":4432,"links":{},"metadata":{"_buckets":{"deposit":"1e4330ac-fb77-431c-a46c-5b3049300ca6"},"_deposit":{"created_by":91,"id":"4432","owners":[91],"pid":{"revision_id":0,"type":"depid","value":"4432"},"status":"published"},"_oai":{"id":"oai:nitech.repo.nii.ac.jp:00004432","sets":["31"]},"author_link":["8722","8722","13614","13615","13616"],"item_10001_biblio_info_28":{"attribute_name":"bibliographic_information","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1996-08","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"4","bibliographicPageEnd":"586","bibliographicPageStart":"581","bibliographicVolumeNumber":"12","bibliographic_titles":[{"bibliographic_title":"Analytical sciences : the international journal of the Japan Society for Analytical Chemistry","bibliographic_titleLang":"en"}]}]},"item_10001_description_36":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"Electroconcentration can be performed using a very simple apparatus and a simple operational procedure. The apparatus is composed of one tube, two electrodes and a power supply. The total sample solution employed for electroconcentration was just 25-40μl. After a tube of silicone rubber (i.d. 1mm, 30-50mm long) was filled with a sample solution, an electric voltage was applied along the tube, and a charged solute was forced to migrate to the end of the tube. With an application of 200-400V for only 2-4min, the concentration of the solute was enhanced up to 10 times. In the present electroconcentration, the sample is concentrated in a few microliters. Electroconcentration by electrode transfer is also proposed.","subitem_description_language":"en","subitem_description_type":"Other"}]},"item_10001_full_name_27":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"8722","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"1000050335080","nameIdentifierScheme":"NRID","nameIdentifierURI":"http://rns.nii.ac.jp/nr/1000050335080"}],"names":[{"name":"北川, 慎也"}]}]},"item_10001_publisher_29":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"The Japan Society for Analytical Chemistry","subitem_publisher_language":"en"}]},"item_10001_relation_34":{"attribute_name":"item_10001_relation_34","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"10.2116/analsci.12.581"}],"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"http://dx.doi.org/10.2116/analsci.12.581","subitem_relation_type_select":"DOI"}}]},"item_10001_source_id_30":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0910-6340","subitem_source_identifier_type":"ISSN"}]},"item_10001_source_id_32":{"attribute_name":"item_10001_source_id_32","attribute_value_mlt":[{"subitem_source_identifier":"AA10500785","subitem_source_identifier_type":"NCID"}]},"item_10001_version_type_33":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kitagawa, Shinya","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"8722","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"1000050335080","nameIdentifierScheme":"NRID","nameIdentifierURI":"http://rns.nii.ac.jp/nr/1000050335080"}]},{"creatorNames":[{"creatorName":"Aragaki, Tsutomu","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"13614","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tsuda, Takao","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"13615","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Matsumoto, Takatoshi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"13616","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-01-23"}],"displaytype":"detail","filename":"AS 12_581.pdf","filesize":[{"value":"393.1 kB"}],"format":"application/pdf","license_note":"1996 cThe Japan Society for Analytical Chemistry","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"本文_fulltext","url":"https://nitech.repo.nii.ac.jp/record/4432/files/AS 12_581.pdf"},"version_id":"0e0c7f5e-90f7-4aa2-8541-ca102470f95f"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"item_resource_type","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Rapid Electroconcentration in a Tube of 25-40 Microliters under a Relatively Low Applied Voltage","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Rapid Electroconcentration in a Tube of 25-40 Microliters under a Relatively Low Applied Voltage","subitem_title_language":"en"}]},"item_type_id":"10001","owner":"91","path":["31"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2012-11-06"},"publish_date":"2012-11-06","publish_status":"0","recid":"4432","relation_version_is_last":true,"title":["Rapid Electroconcentration in a Tube of 25-40 Microliters under a Relatively Low Applied Voltage"],"weko_creator_id":"91","weko_shared_id":-1},"updated":"2025-03-14T04:23:45.718985+00:00"}