{"created":"2023-05-15T12:36:01.788170+00:00","id":5188,"links":{},"metadata":{"_buckets":{"deposit":"22d8c65e-f9f5-430a-81e9-52fa0bf8f6e4"},"_deposit":{"created_by":3,"id":"5188","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"5188"},"status":"published"},"_oai":{"id":"oai:nitech.repo.nii.ac.jp:00005188","sets":["31"]},"author_link":["17545","8610","17539","17541","17543","17542","17544","16261"],"item_10001_biblio_info_28":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2004-05","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"5","bibliographicPageEnd":"1368","bibliographicPageStart":"1366","bibliographicVolumeNumber":"75","bibliographic_titles":[{"bibliographic_title":"REVIEW OF SCIENTIFIC INSTRUMENTS"}]}]},"item_10001_description_36":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"A new field-emission x-ray radiography system based on our design is described. The key component of the system is a triode-type x-ray source with a built-in nanostructured electron source. The electron source is comprised of palladium-induced carbon nanofibers, which continue to field-emit electrons for more than 10 h at 2×10-7Torr with a fluctuation of ±8%. Feedback control of the potential of the electron-extracting electrode, or the gate, reduces the current fluctuation to ±0.5%, but this current regulation does little to improve the image resolution. Our system provides sharp x-ray images of both biological and nonbiological samples.","subitem_description_type":"Other"}]},"item_10001_description_38":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_10001_full_name_27":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{},{}],"names":[{"name":"種村, 眞幸"}]}]},"item_10001_publisher_29":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"American Institute of Physics"}]},"item_10001_relation_34":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"10.1063/1.1711140"}],"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"http://dx.doi.org/10.1063/1.1711140","subitem_relation_type_select":"DOI"}}]},"item_10001_source_id_30":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"00346748","subitem_source_identifier_type":"ISSN"}]},"item_10001_source_id_32":{"attribute_name":"書誌レコードID(NCID)","attribute_value_mlt":[{"subitem_source_identifier":"AA00817730","subitem_source_identifier_type":"NCID"}]},"item_10001_version_type_33":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Senda, S.","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Tanemura, Masaki","creatorNameLang":"en"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"Sakai, Y.","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Ichikawa, Y.","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kita, S.","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Otsuka, T.","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Haga, A.","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Okuyama, F.","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-01-25"}],"displaytype":"detail","filename":"RSI 75_1366.pdf","filesize":[{"value":"432.6 kB"}],"format":"application/pdf","license_note":"Copyright (2004) American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics.The following article appeared in Review of Scientific Instruments, 75(5), pp.1366- 1368 ; 2004 and may be found at http://link.aip.org/link/?rsi/75/1366","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"本文_fulltext","url":"https://nitech.repo.nii.ac.jp/record/5188/files/RSI 75_1366.pdf"},"version_id":"9576fdb6-ab7f-48cd-809a-031d49296296"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"New field-emission x-ray radiography system","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"New field-emission x-ray radiography system","subitem_title_language":"en"}]},"item_type_id":"10001","owner":"3","path":["31"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-11-06"},"publish_date":"2012-11-06","publish_status":"0","recid":"5188","relation_version_is_last":true,"title":["New field-emission x-ray radiography system"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-05-15T14:31:16.835575+00:00"}