{"created":"2023-05-15T12:36:51.929745+00:00","id":6367,"links":{},"metadata":{"_buckets":{"deposit":"6af0b75c-44a1-4aba-903e-57e4efeaf5ce"},"_deposit":{"created_by":91,"id":"6367","owners":[91],"pid":{"revision_id":0,"type":"depid","value":"6367"},"status":"published"},"_oai":{"id":"oai:nitech.repo.nii.ac.jp:00006367","sets":["31"]},"author_link":["8753","7957","22070","8753","9878","9879","573"],"item_10001_biblio_info_28":{"attribute_name":"bibliographic_information","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2015-07-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"7","bibliographicPageEnd":"1172","bibliographicPageStart":"1164","bibliographicVolumeNumber":"98","bibliographic_titles":[{"bibliographic_title":"IEICE Transactions on Communications","bibliographic_titleLang":"en"}]}]},"item_10001_description_36":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"With the rapid increase of various uses of wireless communications in modern life, the high microwave and millimeter wave frequency bands are attracting much attention. However, the existing databases on above 6GHz radio-frequency (RF) electromagnetic (EM) field exposure of biological bodies are obviously insufficient. An in-vivo research project on local and whole-body exposure of rats to RF-EM fields above 6GHz was started in Japan in 2013. This study aims to perform a dosimetric design for the whole-body-average specific absorption rates (WBA-SARs) of unconstrained rats exposed to 6GHz RF-EM fields in a reverberation chamber (RC). The required input power into the RC is clarified using a two-step evaluation method in order to achieve a target exposure level in rats. The two-step method, which incorporates the finite-difference time-domain (FDTD) numerical solutions with electric field measurements in an RC exposure system, is used as an evaluation method to determine the whole-body exposure level in the rats. In order to verify the validity of the two-step method, we use S-parameter measurements inside the RC to experimentally derive the WBA-SARs with rat-equivalent phantoms and then compare those with the FDTD-calculated ones. It was shown that the difference between the two-step method and the S-parameter measurements is within 1.63dB, which reveals the validity and usefulness of the two-step technique.","subitem_description_language":"en","subitem_description_type":"Other"}]},"item_10001_full_name_27":{"attribute_name":"著者別名","attribute_value_mlt":[{"familyNames":[{"familyName":"Wang","familyNameLang":"en"},{"familyName":"王","familyNameLang":"ja"},{"familyName":"オウ","familyNameLang":"ja-Kana"}],"givenNames":[{"givenName":"Jianqing","givenNameLang":"en"},{"givenName":"建青","givenNameLang":"ja"},{"givenName":"ケンセイ","givenNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"8753","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"1000070250694","nameIdentifierScheme":"NRID","nameIdentifierURI":"http://rns.nii.ac.jp/nr/1000070250694"}],"names":[{"name":"Wang, Jianqing","nameLang":"en"},{"name":"王, 建青","nameLang":"ja"},{"name":"オウ, ケンセイ","nameLang":"ja-Kana"}]}]},"item_10001_publisher_29":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Institute of Electronics, Information and Communication Engineers","subitem_publisher_language":"en"}]},"item_10001_relation_34":{"attribute_name":"item_10001_relation_34","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"10.1587/transcom.E98.B.1164"}],"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1587/transcom.E98.B.1164","subitem_relation_type_select":"DOI"}}]},"item_10001_relation_35":{"attribute_name":"item_10001_relation_35","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"130005085028"}],"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://ci.nii.ac.jp/naid/130005085028","subitem_relation_type_select":"NAID"}}]},"item_10001_relation_37":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"http://www.ieice.org/jpn/books/transaction.html"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.ieice.org/jpn/books/transaction.html","subitem_relation_type_select":"URI"}}]},"item_10001_source_id_30":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0916-8516","subitem_source_identifier_type":"ISSN"}]},"item_10001_source_id_32":{"attribute_name":"item_10001_source_id_32","attribute_value_mlt":[{"subitem_source_identifier":"AA11510208","subitem_source_identifier_type":"NCID"}]},"item_10001_version_type_33":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Shi, Jingjing","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"7957","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Chakarothai, Jerdvisanop","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"22070","nameIdentifierScheme":"WEKO"}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifierScheme":"ISNI","affiliationNameIdentifierURI":"http://www.isni.org/isni/"}],"affiliationNames":[{"affiliationNameLang":"ja"}]}],"creatorNames":[{"creatorName":"Wang, Jianqing","creatorNameLang":"en"},{"creatorName":"王, 建青","creatorNameLang":"ja"},{"creatorName":"オウ, ケンセイ","creatorNameLang":"ja-Kana"}],"familyNames":[{"familyName":"Wang","familyNameLang":"en"},{"familyName":"王","familyNameLang":"ja"},{"familyName":"オウ","familyNameLang":"ja-Kana"}],"givenNames":[{"givenName":"Jianqing","givenNameLang":"en"},{"givenName":"建青","givenNameLang":"ja"},{"givenName":"ケンセイ","givenNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"8753","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"1000070250694","nameIdentifierScheme":"NRID","nameIdentifierURI":"http://rns.nii.ac.jp/nr/1000070250694"}]},{"creatorNames":[{"creatorName":"Wake, Kanako","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"9878","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Watanabe, Soichi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"9879","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Fujiwara, Osamu","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"573","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-11-08"}],"displaytype":"detail","filename":"WangJianqing_2015_P2.pdf","filesize":[{"value":"5.3 MB"}],"format":"application/pdf","license_note":"copyright(C)2015 IEICE","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"本文_fulltext","url":"https://nitech.repo.nii.ac.jp/record/6367/files/WangJianqing_2015_P2.pdf"},"version_id":"a19e8e48-f42f-48b8-b24f-723ca3d61345"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"specific absorption rate (SAR)","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"reverberation-chamber (RC) exposure system","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"finite-difference time-domain (FDTD) method","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"keyword/S-parameter measurements","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"item_resource_type","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Dosimetry and Verification for 6-GHz Whole-Body Non-Constraint Exposure of Rats Using Reverberation Chamber","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Dosimetry and Verification for 6-GHz Whole-Body Non-Constraint Exposure of Rats Using Reverberation Chamber","subitem_title_language":"en"}]},"item_type_id":"10001","owner":"91","path":["31"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2018-11-08"},"publish_date":"2018-11-08","publish_status":"0","recid":"6367","relation_version_is_last":true,"title":["Dosimetry and Verification for 6-GHz Whole-Body Non-Constraint Exposure of Rats Using Reverberation Chamber"],"weko_creator_id":"91","weko_shared_id":-1},"updated":"2025-03-27T06:57:09.280399+00:00"}