{"_buckets": {"deposit": "3f8f247e-0b94-416b-a162-0661ba7f8a3d"}, "_deposit": {"created_by": 3, "id": "5390", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "5390"}, "status": "published"}, "_oai": {"id": "oai:nitech.repo.nii.ac.jp:00005390", "sets": ["31"]}, "author_link": ["18752", "8722", "9783", "8644"], "item_10001_biblio_info_28": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2008-06", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "6", "bibliographicPageEnd": "738", "bibliographicPageStart": "735", "bibliographicVolumeNumber": "24", "bibliographic_titles": [{"bibliographic_title": "Analytical sciences : the international journal of the Japan Society for Analytical Chemistry"}]}]}, "item_10001_description_36": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "Dual-gradient capillary electrochromatography (DG-CEC) was developed to provide superior performance with regard to the separation of ionized analytes; in this method, both the eluent composition and the applied voltage are varied during the separation procedure. As for the gradient in the eluent composition, a shift in the pH is employed to control not only the electrophoretic mobility, but also the retention factor of the analytes. The dual-gradient method was shown to be effective in increasing the resolution and reducing the chromatographic period of ionized analytes. Fourteen kinds of o-phthalaldehyde labeled amino acids were separated within 8 min using DG-CEC with multistage enlargement in the applied voltage. The separation efficiency increased particularly for highly retained amino acids in the dual-gradient, as compared to those in the ordinary single-gradient for the eluent.", "subitem_description_type": "Other"}]}, "item_10001_description_38": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_10001_full_name_27": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "8722", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "1000050335080", "nameIdentifierScheme": "NRID", "nameIdentifierURI": "http://rns.nii.ac.jp/nr/1000050335080"}], "names": [{"name": "北川, 慎也"}]}, {"nameIdentifiers": [{"nameIdentifier": "8644", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "1000050176921", "nameIdentifierScheme": "NRID", "nameIdentifierURI": "http://rns.nii.ac.jp/nr/1000050176921"}], "names": [{"name": "Ohtani, Hajime"}]}]}, "item_10001_publisher_29": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "The Japan Society for Analytical Chemistry"}]}, "item_10001_relation_34": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "10.2116/analsci.24.735"}], "subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://dx.doi.org/10.2116/analsci.24.735", "subitem_relation_type_select": "DOI"}}]}, "item_10001_source_id_30": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "09106340", "subitem_source_identifier_type": "ISSN"}]}, "item_10001_source_id_32": {"attribute_name": "書誌レコードID(NCID)", "attribute_value_mlt": [{"subitem_source_identifier": "AA10500785", "subitem_source_identifier_type": "NCID"}]}, "item_10001_version_type_33": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Sakai, Tomoharu", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "18752", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nakagawa, Hiroyuki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "9783", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kitagawa, Shinya", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "8722", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "1000050335080", "nameIdentifierScheme": "NRID", "nameIdentifierURI": "http://rns.nii.ac.jp/nr/1000050335080"}]}, {"creatorNames": [{"creatorName": "Ohtani, Hajime", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "8644", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "1000050176921", "nameIdentifierScheme": "NRID", "nameIdentifierURI": "http://rns.nii.ac.jp/nr/1000050176921"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-01-25"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "AS 24_735.pdf", "filesize": [{"value": "654.7 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensefree": "2008 c The Japan Society for Analytical Chemistry", "licensetype": "license_free", "mimetype": "application/pdf", "size": 654700.0, "url": {"label": "本文_fulltext", "url": "https://nitech.repo.nii.ac.jp/record/5390/files/AS 24_735.pdf"}, "version_id": "21ad553a-a856-45da-91d6-87a239068536"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Dual-Gradient Capillary Electrochromatography by Varying the Mobile Phase Composition and Applied Voltage", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Dual-Gradient Capillary Electrochromatography by Varying the Mobile Phase Composition and Applied Voltage", "subitem_title_language": "en"}]}, "item_type_id": "10001", "owner": "3", "path": ["31"], "permalink_uri": "https://nitech.repo.nii.ac.jp/records/5390", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-11-06"}, "publish_date": "2012-11-06", "publish_status": "0", "recid": "5390", "relation": {}, "relation_version_is_last": true, "title": ["Dual-Gradient Capillary Electrochromatography by Varying the Mobile Phase Composition and Applied Voltage"], "weko_shared_id": 3}
Dual-Gradient Capillary Electrochromatography by Varying the Mobile Phase Composition and Applied Voltage
https://nitech.repo.nii.ac.jp/records/5390
https://nitech.repo.nii.ac.jp/records/53900db3c6fe-cede-4d3c-ad3b-e158c5f88d23
名前 / ファイル | ライセンス | アクション |
---|---|---|
本文_fulltext (654.7 kB)
|
2008 c The Japan Society for Analytical Chemistry
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-11-06 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Dual-Gradient Capillary Electrochromatography by Varying the Mobile Phase Composition and Applied Voltage | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Sakai, Tomoharu
× Sakai, Tomoharu× Nakagawa, Hiroyuki× Kitagawa, Shinya× Ohtani, Hajime |
|||||
著者別名 | ||||||
姓名 | 北川, 慎也 | |||||
著者別名 | ||||||
姓名 | Ohtani, Hajime | |||||
書誌情報 |
Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 巻 24, 号 6, p. 735-738, 発行日 2008-06 |
|||||
出版者 | ||||||
出版者 | The Japan Society for Analytical Chemistry | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 09106340 | |||||
書誌レコードID(NCID) | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA10500785 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | http://dx.doi.org/10.2116/analsci.24.735 | |||||
関連名称 | 10.2116/analsci.24.735 | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | Dual-gradient capillary electrochromatography (DG-CEC) was developed to provide superior performance with regard to the separation of ionized analytes; in this method, both the eluent composition and the applied voltage are varied during the separation procedure. As for the gradient in the eluent composition, a shift in the pH is employed to control not only the electrophoretic mobility, but also the retention factor of the analytes. The dual-gradient method was shown to be effective in increasing the resolution and reducing the chromatographic period of ionized analytes. Fourteen kinds of o-phthalaldehyde labeled amino acids were separated within 8 min using DG-CEC with multistage enlargement in the applied voltage. The separation efficiency increased particularly for highly retained amino acids in the dual-gradient, as compared to those in the ordinary single-gradient for the eluent. | |||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | application/pdf |