WEKO3
アイテム
Rapid Electroconcentration in a Tube of 25-40 Microliters under a Relatively Low Applied Voltage
https://nitech.repo.nii.ac.jp/records/4432
https://nitech.repo.nii.ac.jp/records/443203d8b048-1f07-4fed-9e78-adb4732bd57d
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
1996 cThe Japan Society for Analytical Chemistry
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2012-11-06 | |||||||||||||
タイトル | ||||||||||||||
タイトル | Rapid Electroconcentration in a Tube of 25-40 Microliters under a Relatively Low Applied Voltage | |||||||||||||
言語 | en | |||||||||||||
言語 | ||||||||||||||
言語 | eng | |||||||||||||
資源タイプ | ||||||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||||||
資源タイプ | journal article | |||||||||||||
著者 |
Kitagawa, Shinya
× Kitagawa, Shinya
× Aragaki, Tsutomu
× Tsuda, Takao
× Matsumoto, Takatoshi
|
|||||||||||||
著者別名 | ||||||||||||||
姓名 | 北川, 慎也 | |||||||||||||
bibliographic_information |
en : Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 巻 12, 号 4, p. 581-586, 発行日 1996-08 |
|||||||||||||
出版者 | ||||||||||||||
出版者 | The Japan Society for Analytical Chemistry | |||||||||||||
言語 | en | |||||||||||||
ISSN | ||||||||||||||
収録物識別子タイプ | ISSN | |||||||||||||
収録物識別子 | 0910-6340 | |||||||||||||
item_10001_source_id_32 | ||||||||||||||
収録物識別子タイプ | NCID | |||||||||||||
収録物識別子 | AA10500785 | |||||||||||||
出版タイプ | ||||||||||||||
出版タイプ | VoR | |||||||||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||||||||||
item_10001_relation_34 | ||||||||||||||
関連タイプ | isIdenticalTo | |||||||||||||
識別子タイプ | DOI | |||||||||||||
関連識別子 | http://dx.doi.org/10.2116/analsci.12.581 | |||||||||||||
関連名称 | 10.2116/analsci.12.581 | |||||||||||||
内容記述 | ||||||||||||||
内容記述タイプ | Other | |||||||||||||
内容記述 | Electroconcentration can be performed using a very simple apparatus and a simple operational procedure. The apparatus is composed of one tube, two electrodes and a power supply. The total sample solution employed for electroconcentration was just 25-40μl. After a tube of silicone rubber (i.d. 1mm, 30-50mm long) was filled with a sample solution, an electric voltage was applied along the tube, and a charged solute was forced to migrate to the end of the tube. With an application of 200-400V for only 2-4min, the concentration of the solute was enhanced up to 10 times. In the present electroconcentration, the sample is concentrated in a few microliters. Electroconcentration by electrode transfer is also proposed. | |||||||||||||
言語 | en |